General properties of UPVC at 20 °C.
Physical, mechanical and electrical values of UPVC, and how the working pressure of our valves and fittings changes with temperature.
| Property | Unit | Value | Notes |
|---|---|---|---|
| Specific gravity | – | 1.42–1.43 | Usually 1.43 |
| Shore hardness | – | 70–90 | Comparable to aluminium; varies with temperature. |
| Tensile strength | kg/cm² | 500 | |
| Bending strength | kg/cm² | 950 | Varies with temperature. |
| Modulus of elasticity | kg/cm² | 3.2 × 10⁴ | |
| Izod impact strength | J | 4.7–5.4 | |
| Water absorption | mg/cm² | 1.05 | |
| Elongation at break | % | > 80 | |
| Vicat softening point (5 kg) | °C | 80 | |
| Manufacturing temperature | °C | 110–140 | |
| Coefficient of linear expansion | mm/m·°C | 0.08 | |
| Dielectric strength | kV/mm | > 40 | Electrical equipment must not be earthed through UPVC pipes. |
Pressure and temperature
Working pressure against temperature.
Up to +25 °C our valves and fittings work at 16 bar. Above that, the maximum working pressure falls linearly to 4 bar at +60 °C (DIN 3441 part 1).
For chemical media, check compatibility in the chemical resistance chart and ask our technical team.
Technical centre
More from the technical centre.
- Solvent bondingPrinciples, seven steps, curing times and safety, with photos from real installations.→
- Information about UPVCWhy UPVC, technical characteristics and how our pressure fittings are engineered.→
- Pipe and fitting size standardsOutside diameter and DN, fitting tolerances and thread dimensions.→
- Storage and transportLoading, unloading, stacking heights and long-term storage of pipes.→
- Installation guidesSolvent-welded, flanged and threaded connections, and thermal expansion.→
- Frequently asked questionsPressure classes, drinking water, chemicals, seals and curing times.→
A question we did not cover?
Our technical team helps with product selection, installation and chemical compatibility.